Home | Site Map | Privacy Policy 

ABB Model 8200 NGC Chromatograph

NGC 8200 Benefits

The NGC (Natural Gas Chromatograph) performs on-site gas analysis and heating value computation where current chromatograph technology has been either impractical or unaffordable. This truly “transmitter-like” GC takes up no more room on the pipeline than most multivariable transmitters. The fast analysis cycle and automatic setup features make installation and maintenance unusually easy. The state-of-the-art built-in 32 bit digital controller, the dual electronic carrier pressure regulators, oven-mounted sensors, and other low-noise electronics provide unparalleled sensitivity and months between calibrations.

NGC 8200 Features  

  • •Analysis time-5 minutes
  • •C6+ analysis for up to four streams
  • •Single or dual calibration streams
  • •Classification Class 1, Div. 1, Groups C and D
  • •Operation Temp Range: -20-130 Deg F Repeatability specification 0-130F
  • •Power: 12-24VDC
  • •Power consumption-6 watts nominal, 45 watts startup
  • •Communications: RS232, RS422, RS485, Ethernet and USB hub host and client (optional)
  • •Protocols: Local MMI, Modbus ASCII and RTU, HCIA, DSFG and PTB Printout

    Portable Option Now Available

ABB Level Master

  

Level Master Benefits

  • Supports One or Two Floats to Measure:
  1. Oil Level
  2. Water or Emulsion
  • Also Measures tank Liquid Temperature
  • RS-485 output to host device (LCM, FCU, RTU etc.)
  • Up to 4 Level Masters may be daisy chained together
  • Units are mounted through 3” or 4” Port in top of Tank
  • Intrinsically Safe for installation in Division 1 area
Level Master Features 
 
  • Easy Installation and Initial Calibration
  • No Internal Moving parts
  • No Periodic Calibration (Install it and forget it)
  • Low Power can be run off the same battery and solar panel as the Flow Computer
  • Three Measurements in one sensor- 2 levels and Temperature
  • Vibration and Electronic noise are not a problem
  • Multiple readings and averaging reduces measurement errors due to wave action in the tank.
  • RS-485 output allows multiple units to be connected together

 

 

 

Download Table

NGC Data Sheet

NGC Brochure

NGC Portable Option Data Sheet

NGC Mobile Mount Photos

Level Master Data Sheet

Level Master Communications Data Sheet

 

 

 

 

 

 